A wet riser is permanently charged and pressurised, fed by its own pump and break tank, so BS 9990 servicing covers the plant as well as the pipework: six-monthly inspection, annual pressure test, the pump proved under flow, duty and standby changeover, break tank level and low-water alarms, and every landing valve tested. Sentry Sprinkler Protection carries out wet riser servicing across England from its base in Kettering, ISO 9001 certified.

Wet risers, on our jobs

One photograph of this exact work, from the owner's own sites. Tap any of them.

The full gallery
  1. SurveyFree, and we walk the building
  2. Fixed priceIn writing, with the standard named
  3. First visitDone, recorded and certificated

or call 07927 555475

From first call to certificate

Four steps, the same on every job.

  1. A sprinkler layout drawing marked up on site during a survey
    01

    Free survey

    We look at the building and its records, and tell you what it is due.

  2. A sprinkler installation drawing open on a laptop on site
    02

    Fixed price in writing

    Every item priced line by line. No survey fee, nothing added afterwards.

  3. An engineer installing sprinkler pipework from a scissor lift
    03

    The work, on your dates

    Isolation agreed before anyone arrives, kept as short as the job takes.

  4. A bank of sprinkler alarm valve sets with gauges in a plant room
    04

    Certificate and record

    A certificate and a photographed defect list, ready for your insurer.

  5. Start

    Book the free survey

    Tell us the building. We will tell you what it is due.

    Book a free survey

Covered on every visit

BS 9990

  • Six-monthly and annual testing to BS 9990
  • Wet riser pump testing, including duty and standby changeover
  • Break tank, level and low-water alarm checks
  • Installation, repair and pump replacement

When it is due

  1. Six-monthly inspection
  2. Annual pressure test
  3. Pump performance test

The duty sits with whoever controls the premises under the Fire Safety Order 2005. It can be delegated as work, not as responsibility, which is why the certificate matters as much as the visit. How compliance works

What actually goes wrong with a wet riser

A wet riser is a riser, a pump, a tank and an alarm path, and it is only working when all four are. Testing them one at a time proves almost nothing.

  • The pump starts but will not make its duty

    A start test proves the set turns over. It says nothing about whether it delivers the pressure and flow the riser was designed around. Only a test under flow answers that, and it is the test most often quietly replaced by a start.

  • The break tank does not refill, and nothing says so

    The tank feeds the pump, the inlet refills the tank, and the low level alarm is what tells anybody the balance has failed. A stuck float valve or an unproved level alarm means the riser has water until it suddenly does not.

  • Pressure at the landing valves is wrong

    A wet riser is permanently charged, so the pressure at a low level landing valve has to be controlled or it is dangerous to use. Pressure reducing valves drift out of adjustment and are rarely checked against what they are supposed to deliver.

  • The alarms are not routed anywhere

    Pump running, pump failed, low tank level. Each of those is only useful if it arrives somewhere a person sees it. On buildings that have changed managing agent, the signal frequently terminates at a panel nobody now monitors.

Free survey · fixed price in writing

Tell us what you need. We will tell you what it takes.

Four quick taps and your details. A free survey and a fixed price in writing, with no survey fee and no obligation.

Call 07927 555475

Mon to Fri, 7am to 5pm. Emergencies any hour.

What do you need?

Pick one. The next questions follow from it.

What kind of building is it?
How tall is the building?
What is happening?
Which part needs looking at?
Where is the project?
When is it due?
How soon do you need us?
Who do we ring back?

Usually the same working day. We never share your details.

No survey fee, no obligation. ISO 9001:2015 certified.

Questions we get asked

How is a wet riser different from a dry riser?

A dry riser is empty until the brigade connects to it. A wet riser is always full and pressurised, fed by its own pump and tank. Buildings above roughly 50 metres need a wet riser, because a brigade pump cannot reach that height.

What does wet riser maintenance include?

Six-monthly and annual testing to BS 9990, the pump run and proved under flow, duty and standby changeover, break tank level and low-water alarm checks, and every landing valve tested.

Can wet riser testing be done out of hours?

Usually we have to. Testing a wet riser means running water through an occupied building, so most of this work happens in the evening or at a weekend.

How is the pump proved on a wet riser?

Under flow, not by watching it start. The test measures whether the set can deliver the pressure and flow the system was designed for at the highest outlet, which is the only thing that proves it will work in a fire. A pump that starts and runs can still fail that test.

What happens to the water in the system during servicing?

As little as possible. A wet riser is permanently charged, so where a valve or a section has to come out we isolate the smallest part we can and drain that alone. You get told beforehand what will be out of service and for how long.

Do the tanks and level alarms get checked too?

The level alarms yes, on every visit, because a wet riser is only as good as the water behind it. The tanks themselves run on a separate cycle at three, five and ten years and are quoted separately, which is a distinction people miss until an inspection asks for the tank record.

Wet and dry riser servicing, town by town

The towns where this is the work we are asked for most. Each page covers the buildings there and what the journey means for a visit.

Every town we cover

The published documents behind this page

Every interval and threshold on this page comes from one of these. Links go to the publisher, not to a copy of the document.

British Standards are copyright documents and most are bought rather than read free. We hold the ones we work to. If you need to know what one of them says about your building, ask us rather than buying it.

See a wet riser at work, in 3D

A wet riser is always full, fed by its own pump and break tank. Start a fire and watch the brigade connect on the fire floor.

Illustration only. Not a design.

Loading the 3D model

Drag to turn it. Ctrl + scroll to zoom. Click any part to see what it is.

The building

New blocks above 11 metres need sprinklers. Above 18 metres, a fire main as well.

Fire protection
Riser

Watch it happen, one step at a time.

Click any part of the model, or any part in the list below, to see what it does and how often it is tested.

Your system

What it needs
  • Weekly tank level check, pump start test, alarm motor test, system checks
  • Quarterly flow switch and alarm test
  • Six-monthly riser inspection
  • Annual tank inspection and clean, pump performance test under flow, valve set strip, clean and rebuild, full service, riser pressure test
  • At each service Riser pump proved under flow

Illustration only. This model shows how a fire sprinkler system works. It is not a design for any real building, and the layout, pipe sizes, head spacing, water supply and riser positions in it are not the ones your building would need. Every real system is designed for its building after a survey, to BS EN 12845, BS 9251 or BS 9990.

Open the 3D builder on its own page

Certified, and audited on a schedule.

ISO 9001, certified by BRE Global and accredited by UKAS. Somebody independent audits how every job is planned, recorded and signed off, on a schedule.

BRE Global Certification and UKAS Management Systems 0007

ISO 9001:2015

Certified by BRE Global, accredited by UKAS

An audited quality management system. It means the way a job is planned, recorded and signed off is itself inspected by somebody independent, on a schedule.

Working to BS EN 12845, BS 9251 and BS 9990. If your insurer or fire risk assessor wants the certificates themselves, ring us and we will send them over.

5.0 on Google

3 reviews, and every one of them five stars.

  • Mike C. Weekly maintenance, testing and repair

    Sentry Sprinkler Protection have recently taken over the weekly maintenance, testing and repair of the […] sprinkler equipment. They are providing a excellent service, good value and they are also very helpful when on site.

    5 stars on Google

  • Lewis W. Sprinkler installation, warehouse

    Had them install a full sprinkler system across one of our warehouses, and couldn't be happier. They were professional from start to finish and the on-site team were genuinely friendly to work with. […] Highly recommend if you would need your building or warehouse properly fire-protected.

    5 stars on Google

  • Sam E. Sprinkler pipework installation

    Couldn't recommend [Sentry] enough. Their work ethic, consistent efficient install of the pipework and overall approach to a project should be something every sub-contractor strives to mirror. Marius is incredibly approachable and methodical in his work with laydown areas kept very neat and tidy and all work carried out in a safe manner.

    5 stars on Google

Tell us the building. We will tell you what it is due.

No survey fee to find out where you stand. Describe the site and we will tell you which intervals apply and what the visit involves.

Based
37 Dickens Drive, Kettering, NN16 9EG
Covering
Kettering · Corby · Wellingborough · Northampton · Rushden · Daventry · Market Harborough · Bedford and England, from our base in Kettering
Office hours
Monday to Friday, 7am to 5pm. Emergency line any hour.

What do you need?
Type of building optional
Who do we come back to?

    If it is urgent, ring rather than write. We are on the phone Monday to Friday, 7am to 5pm, and outside those hours the same number reaches the emergency line.

    Or send it straight to us

    Or just ring 07927 555475 and talk it through. Mon to Fri, 7am to 5pm. Emergencies any hour.